What size copper equipment grounding conductor is required for a circuit protected by a 60 ampere circuit breaker?

What size copper equipment grounding conductor is required for a circuit protected by a 60 ampere circuit breaker?

12 AWG
What is the minimum size copper equipment grounding conductor required for a circuit where the overcurrent device is 60 amps? A: 12 AWG.

What article is grounding covered in?

Article 250
Article 250 covers the grounding requirements for providing a path to the earth to reduce overvoltage from lightning, and the bonding requirements for a low-impedance fault current path back to the source of the electrical supply to facilitate the opera- tion of overcurrent devices in the event of a ground fault.

How do you size a bonding conductor?

Selection of a bonding conductor size is governed by Rule 10-814(1). This Rule states the following: “10-814(1) The size of a bonding conductor shall be not less than that given in Table 16, but in no case does it need to be larger than the largest ungrounded conductor in the circuit.”

Does the NEC permit two wire Romex stapled on edge?

What are the colors of the conductors in nonmetallic-sheathed cable for 2 and 3 wire cable? Does the NEC permit 2-wire Romex stapled on edge? no NEC 334.30. 14d.)

What is the title of NEC Article 200?

Article 200 covers the identification of terminals, grounded conductors in premises wiring systems, and identification of grounded conductors. The wiring systems of all premises must have a grounded conductor that is identified as stated in Section 200.6.

Does the size of a grounding wire matter?

The ground wire is not always the same size as hotwire or neutral wire. It can be a size bigger or smaller than other wires. The bigger ground wire doesn’t do any harm to the system. It’ll only cost more to use a bigger ground wire.

What is the minimum size of a bonding conductor?

2. The main protective bonding conductors shall have a cross-sectional area of not less than half that required for the earthing conductor and not less than 6mm².

What are the tables in Article 250 of NEC?

Article 250 is a foundational pillar of NFPA 70®, National Electrical Code® (NEC®), and the tables within Article 250 are critical resources for sizing the wiring for the grounding and bonding of an electrical system. Becoming more familiar

What is Article 250 of NFPA 70 NEC?

Article 250 is a foundational pillar of NFPA 70®, National Electrical Code® (NEC®), and the tables within Article 250 are critical resources for sizing the wiring for the grounding and bonding of an electrical system. Becoming more familiar with the proper use of these tables can help installers ensure

What are the NEC requirements for grounding and bonding?

What is the goal of the NEC requirements for grounding and bonding? Section 250.4 states the general requirements for grounding and bonding of electrical systems for both grounded and ungrounded systems.

Which is the foundational pillar of the NEC?

Article 250 is a foundational pillar of the NEC; it should be studied in its entirety to make sure that both grounding and bonding are done properly. A few critical resources that you should use regularly are Tables 250.66, 250.102 (C) (1), and 250.122.