Is Q exactive an Orbitrap?

Is Q exactive an Orbitrap?

The Q Exactive mass spectrometer, combining high-performance quadrupole precursor selection with HR/AM Orbitrap detection, can be widely used in metabonomics, proteomics, environmental and food safety, clinical research, and forensic toxicology.

What is Q Exactive Plus?

Q Exactive Plus (Q) With a fast scan speed and multiplexing capabilities, the Q Exactive Plus mass spectrometer is an outstanding detector for fast chromatography separation techniques. The superior quality of Q Exactive Plus MS/MS data enables identification and quantitation of more compounds with greater confidence.

What is LTQ Orbitrap?

LTQ Orbitrap Velos is a hybrid mass spectrometer incorporating the LTQ Velos™ dual cell linear trap and the Orbitrap™ analyzer. The LTQ Orbitrap is a high performance LC-MS and MSn system, combining rapid LTQ ion trap data acquisition with high mass accuracy Orbitrap mass analysis.

What is C trap?

The C-Trap® is the world’s first instrument that allows simultaneous manipulation and visualization of single-molecule interactions in real time. It combines high-resolution optical tweezers, fluorescence, and label-free microscopy, and an advanced microfluidics system in a truly integrated and correlated solution.

What is high resolution mass spectrometry?

High-resolution mass spectrometry (HRMS) uses mass spectrometers capable of high resolution, as well as high mass accuracy measurements. These instruments can be used to distinguish between compounds with the same nominal mass, determine elemental compositions, and identify unknowns.

What is the C trap?

Who invented Orbitrap?

Alexander Makarov
Alexander Makarov, inventor of the Orbitrap mass analyzer, discuss 20 years of Orbitrap innovations.

What is the difference between ion trap and Orbitrap?

The Orbitrap is a modified Kingdon ion trap that consists of two endcap electrodes and a central “spindle” electrode. Ions entering the Orbitrap are trapped by their attraction to the spindle electrode, which is contrasted by their inertia, and begin to orbit around the spindle electrode.

Why is high resolution of interest in mass spectrometry?

High-resolution mass spectrometry (HRMS) provides the highest possible precision of m/z measurement using different analyzers such as time of flight, Orbitrap [112], or Fourier transform ion cyclotron resonance. Standard resolution is usually at least 20 times higher than in low-resolution MS systems [95].

Which is Q Exactive orbitrap mass spectrometer is best for my lab?

With the combination of scan speed, high resolution, mass accuracy, spectral quality, and sensitivity you can achieve quantifiable certainty. What’s inside a Q Exactive Orbitrap Mass Spectrometer? Which Q Exactive Orbitrap Mass Spectrometer is best for my lab?

Is the Thermo Scientific mass spectrometer powered by Orbitrap?

Welcome to the Thermo Scientific™ Exactive™ Series system! Exactive Series systems are members of the Thermo Scientific family of mass spectrometer (MS) detectors that are powered by Orbitrap™ technology.

What does the Thermo Scientific Q mass spectrometer do?

The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased performance and new options…

What kind of mass analyzer does Orbitrap use?

Orbitrap mass analyzer: The Orbitrap mass analyzer offers unprecedented high resolution accurate mass (HRAM) analysis of ions as a function of their rotational frequencies; these data are converted to mass spectra using fast Fourier transforms (FFTs).